72-26 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | SD paper exit section | ||
JAM code | 72-26 | ||
Detection timing | <When FS-534+SD-511 is installed> The fold exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. | ||
<When FS-535+SD-512 is installed> The SD exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper. | |||
Misfeed processing location | -Front door -Stacker unit | ||
Relevant parts | <When FS-534+SD-511 is installed> -Fold exit sensor (PS12) -SD drive board (SDDB) -FS control board (FSCB) | ||
<When FS-535+SD-512 is installed> -Paper transport belt motor (M34) -SD exit sensor (PS12) -SD drive board (SDDB) -FS control board (FSCB) |
(2)Procedure When FS-534+SD-511 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS12 I/O check, sensor check | SDDB J9-2 (ON) | SD-511 G-5 |
3 | Replace SDDB (Part# A3ERPP6J03) | – | – |
4 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.3.9 SD-511)
When FS-535+SD-512 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS12 I/O check, sensor check | SDDB J9-2 (ON) | SD-512 4-G |
3 | M34 operation check | SDDB CN1-1 to 11 | SD-512 17-D |
4 | Replace SDDB (Part# A3ERPP6J03) | – | – |
5 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.3.12 SD-512)
K1.10.13 (Link to the Field Service Manual)