How Can We Help?

72-26 (bizhub C554e/C454e)

You are here:

Contents

JAM typeSD paper exit section
JAM code72-26
Detection timing<When FS-534+SD-511 is installed>
The fold exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
<When FS-535+SD-512 is installed>
The SD exit sensor (PS12) is not turned OFF even after the set period of time has elapsed after it is turned ON by the paper.
Misfeed processing location• Front door
• Stacker unit
Relevant parts<When FS-534+SD-511 is installed>
• Fold exit sensor (PS12)
• SD drive board (SDDB)
• FS control board (FSCB)
<When FS-535+SD-512 is installed>
• Paper transport belt motor (M34)
• SD exit sensor (PS12)
• SD drive board (SDDB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+SD-511 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS12 I/O check, sensor checkSDDB J9-2 (ON)SD-511 5-G
3Replace SDDB (Part# A3ERPP6J03)
4Replace FSCB (Part# A3EPPPBE01)

When FS-535+SD-512 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS12 I/O check, sensor checkSDDB J9-2 (ON)SD-512 4-G
3M34 operation checkSDDB CN1-1 to 11SD-512 17-D
4Replace SDDB (Part# A3ERPP6J03)
5Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.10.14 (Link to the Field Service Manual)

Table of Contents