72-41 (bizhub C554e/C454e)
Contents
JAM type | ZU section | ||
JAM code | 72-41 | ||
Detection timing | <When FS-535+ZU-606 is installed> When the second fold is started in Z-fold mode, the conveyance sensor (PS601) is not switched from ON to OFF by the paper after the set period of time has elapsed. | ||
Misfeed processing location | • Front door (72-41) • Z folding/conveyance unit (72-41) | ||
Relevant parts | • Conveyance sensor (PS601) • ZU control board (ZUCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS601 I/O check, sensor check | ZUCB CN4-2 (ON) | ZU-606 4-C |
3 | Replace ZUCB (Part# A109H01002) | – | – |
- Link to the wiring diagram (N.3.14 ZU-606)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.20 (Link to the Field Service Manual)