How Can We Help?

72-43 (bizhub C754e/C654e)

You are here:

Contents

JAM typePK section
JAM code72-43
Detection timing<When FS-534+PK-520 is installed>
The punch position sensor (PS2) is not unblocked after a lapse of a given time after the punch drive motor (M1) starts rotating.
<When FS-535+PK-521 is installed>
The PK punch hole position sensor/2 (PS301) is not unblocked after a lapse of a given time after the punch drive motor (M301) starts rotating.
Misfeed processing locationFront door
Relevant parts<When FS-534+PK-520 is installed>
• Punch drive motor (M1)
• Punch position sensor (PS2)
• FS control board (FSCB)
<When FS-535+PK-521 is installed>
• Punch drive motor (M301)
• PK punch hole position sensor/2 (PS301)
• Punch control board (PKCB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534+PK-520 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkFSCB J7-2 (ON)FS-534 (PK-520) 6-K
3M1 operation checkFSCB J7-7 to 8FS-534 (PK-520) 7-K
4Replace FSCB (Part# A3EPPPBE01)

When FS-535+PK-521 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS301 I/O check, sensor checkPKCB CN36-5 (ON)PK-521 3-C
3M301 operation checkPKCB CN35-1 to 3PK-521 2-C
4Replace PKCB (Part# A2YRH10103)
5Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.10.20 (Link to the Field Service Manual)

Table of Contents