72-44 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | ZU section | ||
JAM code | 72-44 | ||
Detection timing | <When FS-535+ZU-606 is installed> The exit sensor (PS609) is not turned ON even after the set period of time has elapsed after the leading, trailing, or side edge sensor on the paper size detect board (PSDTB) is turned ON by the paper. | ||
Misfeed processing location | Front door | ||
Relevant parts | -Exit sensor (PS609) -Paper size detect board (PSDTB) -ZU control board (ZUCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS609 I/O check, sensor check | ZUCB CN4-8 (ON) | ZU-606 5-C |
3 | PSDTB I/O check, sensor check | ZUCB CN2-1 to 10 | ZU-606 9 to 10-C to D |
4 | Replace ZUCB (Part# A109H01002) | – | – |
- Link to the wiring diagram (N.3.14 ZU-606)
K1.10.21 (Link to the Field Service Manual)