How Can We Help?

72-70 (bizhub 558/458/368/308)

You are here:

Contents

JAM typeMisfeed at PK JAM
JAM code72-70
JAM detection timing<When FS-533+PK-519 is installed>
The paper feed sensor (PS201) is not turned OFF even after the set period of time has elapsed after it is turned ON.
Misfeed processing locationFinisher punch section
Relevant parts• Fusing motor (M3)
• Paper conveyance motor (M101)
• Paper feed sensor (PS201)
• FS control board (FSCB)

 Procedure

 When FS-533+PK-519 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS201 I/O check, sensor checkPKCB CN204FS-533 (PK-519) 5-C
3M3 operation check (bizhub 558/458)MFPB CN14E-9 (REM)MFPB CN41E-12 (LOCK)2-C
M3 operation check (bizhub 368/308)MFPB CN8E-9 (REM)MFPB CN8E-12 (FGP)2-C
4M101 operation checkFSCB CN101FS-533 6-J
5Replace FSCB. (Part# A2YUPPH901(Model No. A2YU-WY1) or A2YUPPXN00 (Model No. A2YU-WY2))