72-81 (bizhub 754e/654e)
Contents
JAM type | FS staple section | ||
JAM code | 72-81 | ||
Detection timing | <When FS-535 is installed> The stapler position sensor/4 (PS53) is not blocked even after the set period of time has elapsed after the stapler motor (M14) operation started. | ||
Misfeed processing location | Front door | ||
Relevant parts | <When FS-535 is installed> • Stapler motor (M14) • Stapler position sensor/4 (PS53) • FS control board (FSCB) |
(2)ProcedureWhen FS-535 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | M14 operation check | FSCB CN15-1 to 2 | FS-535 8 to 9-D |
3 | PS53 I/O check, sensor check | FSCB CN23-12 (ON) | FS-535 12-L |
4 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.2.7 Finisher FS-535)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.32 (Link to the Field Service Manual)