72-84 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
When FS-539SD is installed
Contents
JAM type | Misfeed at SD staple section (When FS-539SD is installed) | |
JAM code | 72-84 | |
JAM detection timing | 72-84: The stapler home position sensor/Rr does not turn ON even after the lapse of a given period of time after the staple operation started. | |
Misfeed processing location | -Front door -Stacker unit | |
Relevant parts | -Stapler unit -SD control board (SDCB) -FS control board (FSCB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | Replace the stapler unit. (Part# A3EP560100) | – | – |
3 | Replace SDCB. (Part# A3ERPP6J03) | – | – |
4 | Replace FSCB. (Part# AAR4PP8201) | – | – |
When FS-540SD is installed
Contents
JAM type | Misfeed at SD staple section (When FS-540SD is installed) | |
JAM code | 72-84 | |
JAM detection timing | 72-84: The stapler home position sensor/Rr does not turn ON even after the lapse of a given period of time after the staple operation started. | |
Misfeed processing location | -Front door -Stacker unit | |
Relevant parts | -Stapler unit -SD control board (SDCB) -FS control board (FSCB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | Replace the stapler unit. (Part# AAR5PPE200) | – | – |
3 | Replace SDCB. (Part# A3ERPP6J03) | – | – |
4 | Replace FSCB. (Part# AAR5PPD401) | – | – |