How Can We Help?

72-87 (bizhub 558/458/368/308)

You are here:

Contents

JAM typeMisfeed at SD transport section
JAM code72-87
JAM detection timing<When FS-536SD or FS-537SD is installed>
The center staple/fold stacker paper detect sensor (PS3) is not turned ON even after the set period of time has elapsed after the SD entrance sensor (PS1) is turned ON (blocked) by the paper.
Misfeed processing location• Front door
• Stacker unit
Relevant parts<When FS-536SD or FS-537SD is installed>
• SD entrance sensor (PS1)
• Center staple/fold stacker paper detect sensor (PS3)
• SD control board (SDCB)
• FS control board (FSCB)

 Procedure

 When FS-536SD or FS-537SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS1 I/O check, sensor checkSDCB J4-3 (ON)FS-536/FS-536SD 4-KFS-537/FS-537SD 5-L
3PS3 I/O check, sensor checkSDCB J9-2 (ON)FS-536/FS-536SD 5-PFS-537/FS-537SD 5-P
4Replace SDCB. (FS-536SD  / FS-537SD) (Part# A3ERPP6J03)
5Replace FSCB. (FS-536SD Part# A87GPP0V00 / FS-537SD Part# A87HPP9M01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.16.24 (Link to the Field Service Manual)