How Can We Help?

75-43 (bizhub 658e/558e/458e/368e/308e)

You are here:

Contents

JAM typeMisfeed at RU section
JAM code75-43
JAM detection timing<When FS-536, FS-536SD, FS-537, or FS-537SD is installed>
The RU entrance sensor (PS2) is not turned OFF (unlocked) even after the set period of time has elapsed after it is turned ON (blocked).
Misfeed processing locationHorizontal transport cover
Relevant parts<When FS-536, FS-536SD, FS-537, or FS-537SD is installed>
• RU entrance sensor (PS2)
• FS control board (FSCB)

 Procedure

 When FS-536 or FS-536SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkFSCB J6-7 (ON)FS-536/FS-536SD 12-K
3Replace FSCB. (Part# A87GPP0V00)

 When FS-537 or FS-537SD is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkFSCB J8<B>-15 (ON)FS-537/FS-537SD 9-K
3Replace FSCB. (Part# A87HPP9M01)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.1.16.26 (Link to the Field Service Manual)

Table of Contents