75-43 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at RU section | ||
JAM code | 75-43 | ||
JAM detection timing | <When FS-534 or FS-534SD is installed> The RU entrance sensor (PS2) is not turned OFF (unlocked) even after the set period of time has elapsed after it is turned ON (blocked). | ||
Misfeed processing location | Horizontal transport cover | ||
Relevant parts | -RU entrance sensor (PS2) -FS control board (FSCB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | FSCB J6-7 (ON) | FS-534 6-K |
3 | Replace FSCB. (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (FS-534)
K.1.10.19 (Link to the Field Service Manual)