75-43 (bizhub C368/C308/C258)
Contents
JAM type | Misfeed at RU section | ||||
JAM code | 75-43 | ||||
JAM detection timing | <When FS-534 or FS-534SD is installed> The RU entrance sensor (PS2) is not turned OFF (unlocked) even after the set period of time has elapsed after it is turned ON (blocked). | ||||
Misfeed processing location | Horizontal transport cover | ||||
Relevant parts | • RU entrance sensor (PS2) • FS control board (FSCB) |
Procedure
When FS-534 or FS-534SD is installed
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | FSCB J6-7 (ON) | FS-534 6-K |
3 | Replace FSCB. (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (FS-534)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.16.19 (Link to the Field Service Manual)