How Can We Help?

75-43 (bizhub C554e/C454e)

You are here:

(1)Contents

JAM typeRU section
JAM code75-43
Detection timing<When FS-534 is installed>
The RU entrance sensor (PS2) is not unlocked even after the set period of time has elapsed after it locked.

<When FS-535 is installed>
The RU transport sensor (PS60) is not unlocked even after the set period of time has elapsed after it locked.
Misfeed processing locationHorizontal transport cover
Relevant parts<When FS-534 is installed>
• RU entrance sensor (PS2)
• FS control board (FSCB)

<When FS-535 is installed>
• RU transport sensor (PS60)
• RU control board (RUCB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkFSCB J6-7 (ON)FS-534 6-K
3Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS60 I/O check, sensor checkRUCB CN206-3 (ON)FS-535 3-P to Q
3RUCB ICP1 conduction check
4Replace RUCB (Part# A2Y1H10101)
5Replace FSCB (Part# A2Y1H10002)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.10.42 (Link to the Field Service Manual)

Table of Contents