75-43 (bizhub C554e/C454e)
(1)Contents
JAM type | RU section | ||
JAM code | 75-43 | ||
Detection timing | <When FS-534 is installed> The RU entrance sensor (PS2) is not unlocked even after the set period of time has elapsed after it locked. <When FS-535 is installed> The RU transport sensor (PS60) is not unlocked even after the set period of time has elapsed after it locked. | ||
Misfeed processing location | Horizontal transport cover | ||
Relevant parts | <When FS-534 is installed> • RU entrance sensor (PS2) • FS control board (FSCB) <When FS-535 is installed> • RU transport sensor (PS60) • RU control board (RUCB) • FS control board (FSCB) |
(2)ProcedureWhen FS-534 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS2 I/O check, sensor check | FSCB J6-7 (ON) | FS-534 6-K |
3 | Replace FSCB (Part# A3EPPPBE01) | – | – |
- Link to the wiring diagram (N.3.8 FS-534)
When FS-535 is installed
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS60 I/O check, sensor check | RUCB CN206-3 (ON) | FS-535 3-P to Q |
3 | RUCB ICP1 conduction check | – | – |
4 | Replace RUCB (Part# A2Y1H10101) | – | – |
5 | Replace FSCB (Part# A2Y1H10002) | – | – |
- Link to the wiring diagram (N.3.10 FS-535)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.10.42 (Link to the Field Service Manual)