JAM typeRU section
JAM code75-43
Detection timing<When FS-534 is installed>
The RU entrance sensor (PS2) is not unlocked even after the set period of time has elapsed after it locked.
<When FS-535 is installed>
The RU transport sensor (PS60) is not unlocked even after the set period of time has elapsed after it locked.
Misfeed processing locationHorizontal transport cover
Relevant parts<When FS-534 is installed>
• RU entrance sensor (PS2)
• FS control board (FSCB)
<When FS-535 is installed>
• RU transport sensor (PS60)
• RU control board (RUCB)
• FS control board (FSCB)

 (2)ProcedureWhen FS-534 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS2 I/O check, sensor checkFSCB J6-7 (ON)FS-534 6-K
3Replace FSCB (Part# A3EPPPBE01)

When FS-535 is installed

StepActionControl signalLocation of electrical component
1Initial check items
2PS60 I/O check, sensor checkRUCB CN206-3 (ON)FS-535 3-P to Q
3RUCB ICP1 conduction check
4Replace RUCB (Part# A2Y1H10101)
5Replace FSCB (Part# A2Y1H10002)