75-43 (bizhub C759/C659)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
| JAM type | Misfeed at RU section | ||
| JAM code | 75-43 | ||
| JAM detection timing | <When FS-536, FS-536SD, FS-537, or FS-537SD is installed> The RU transport sensor (PS60) is not turned OFF (unlocked) even after the set period of time has elapsed after it is turned ON (blocked). | ||
| Misfeed processing location | Horizontal transport cover | ||
| Relevant parts | <When FS-536, FS-536SD, FS-537, or FS-537SD is installed> -RU transport sensor (PS60) -FS control board (FSCB) |
Procedure
When FS-536 or FS-536SD is installed
| Step | Action | Control signal | Location of electrical component |
|---|---|---|---|
| 1 | Initial check items | – | – |
| 2 | PS60 I/O check, sensor check | FSCB J6-7 (ON) | FS-536/FS-536SD 12-K |
| 3 | Replace FSCB. (Part# A87GPP0V00) | – | – |
When FS-537 or FS-537SD is installed
| Step | Action | Control signal | Location of electrical component |
|---|---|---|---|
| 1 | Initial check items | – | – |
| 2 | PS60 I/O check, sensor check | FSCB J8<B>-15 (ON) | FS-537/FS-537SD 9-K |
| 3 | Replace FSCB. (Part# A87HPP9M01) | – | – |
L.1.10.25 (Link to the Field Service Manual)