How Can We Help?

92-02 (bizhub C368/C308/C258)

You are here:

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-02
JAM detection timingFor the second-side feed of paper in the duplex mode, loop forming has not been complete before the second side of a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop.
– Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset.
Misfeed processing locationRight door
Relevant parts• Transport motor (M1) 
• ADU transport clutch (CL6) 
• Registration sensor (PS1) 
• Front side board (FRB) 
• MFP board (MFPB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS1 I/O check, sensor checkFRB CN8-3 (ON)6-L
3CL6 operation checkMFPB CN15EA-13 (ON)7-C
4M1 operation checkMFPB CN8E-3 (REM)MFPB CN8E-6 (LOCK)2-C
5Replace FRB. (Part# A7PUH00500)
6Replace MFPB. (Part# A7PUH02123)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.18.1 (Link to the Field Service Manual)

Table of Contents