92-02 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at duplex pre-registration section |
JAM code | 92-02 |
JAM detection timing | For the second-side feed of paper in the duplex mode, loop forming has not been complete before the second side of a sheet enters the registration roller because the rise timing of load to perform registration is earlier than the rise timing of load to form a loop. |
– | Paper jam of a sheet of paper left at the duplex pre-registration section results, if a sheet of paper is determined to exist at a position detected when the main power switch is turned ON, a door is opened and closed, or a misfeed or malfunction is reset. |
Misfeed processing location | Right door |
Relevant parts | -ADU transport motor/2 (M26) -Registration sensor/1 (PS1) -Registration sensor/2 (PS72) (bizhub C650i/C550i) -Base board (BASEB) |
Procedure
Step | Action | Control signal | Location of electrical component |
---|---|---|---|
1 | Initial check items | – | – |
2 | PS1 I/O check, sensor check | BASEB CN15E-9 (ON) | 4-C |
3 | PS72 I/O check, sensor check | BASEB CN15E-19 (ON) | 5-C |
4 | M26 load check: Check code: 85 Multi code: 6, 7, 8, 9 (bizhub C650i), 6, 8, 9 (bizhub C550i), 6, 7, 9 (bizhub C450i) | BASEB CN18E-11 to 14 | 6-C |
5 | Replace BASEB. (Part# AA7NH02102) | – | – |
L.1.10.1 (Link to the Field Service Manual)