How Can We Help?

92-03 (bizhub 754e/654e)

You are here:

Contents

JAM typeDuplex pre-registration section
JAM code92-03
Detection timingThe OHP sensor (PS40) is not turned ON even after the lapse of a given period of time after a duplex paper feed sequence has been started.
Misfeed processing location• Upper right door 
• Duplex door
Relevant parts• ADU transport motor/1 (M31) 
• ADU transport motor/2 (M32) 
• Registration sensor (PS38) 
• OHP sensor (PS40) 
• Paper feed/transport drive board (PFTDB) 
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS38 I/O check, sensor checkPFTDB CN3-6 (ON)4-P
3PS40 I/O check, sensor checkPFTDB CN3-3 (ON)4-P
4M32 operation checkPFTDB CN4-10 to 138-P
5M31 operation checkPFTDB CN4-14 to 178-P
6PFTDB ICP3 or ICP11 conduction check
7Replace PFTDB (Part# A2X0H00202)
8PRCB ICP13 conduction check
9Replace PRCB (Part# A55VH00105)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.11.1 (Link to the Field Service Manual)

Table of Contents