How Can We Help?

92-03 (bizhub 958/808)

You are here:

Contents

JAM typeMisfeed at duplex pre-registration section
JAM code92-03
JAM detection timingThe leading edge of the paper does not turn ON the OHP sensor (PS40) even after the lapse of a given period of time after a duplex paper feed sequence has been started.
Misfeed processing location• Upper right door 
• Duplex door
Relevant parts• ADU transport motor/1 (M31) 
• ADU transport motor/2 (M32) 
• Registration sensor (PS38) 
• OHP sensor (PS40) 
• Paper feed/transport drive board (PFTDB) 
• MFP board (MFPB)

 Procedure

StepActionControl signalLocation of electrical component
1Initial check items
2PS38 I/O check, sensor checkPFTDB CN2-6 (ON)4-P
3PS40 I/O check, sensor checkPFTDB CN2-3 (REM)4-P
4M31 operation checkPFTDB CN28-14 to 178-P
5M32 operation checkPFTDB CN28-10 to 137-P
6PFTDB F10 conduction check
7Replace PFTDB. (Part# A796H00200)
8Replace MFPB. (Part# A796H02003)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.1.11.1 (Link to the Field Service Manual)

Table of Contents