92-40 (bizhub 364e/284e/224e)
Contents
JAM type | Misfeed at duplex pre-registration section |
JAM code | 92-40 |
Detection timing | For the second-side feed of paper in the duplex mode, the image write start signal permit continues to be disabled for a predetermined period of time after the timing of the image write start signal output. |
– | In case paper position is detected as locating properly after main power switch is turned ON, door and cover are opened / closed or jam/trouble reset is done, it is regarded as paper jam at duplex pre-registration section. |
Misfeed processing location | Right door |
Relevant parts | • Transport motor (M1) • ADU transport clutch (CL6) • Registration sensor (PS1) • Front side board (FRB) • Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS1 I/O check, sensor check | FRB CN8-3 (ON) | 4 to 5-L |
3 | CL6 operation check | PRCB CN12-11 (ON) | 25-C |
4 | M1 operation check | PRCB CN31-2 (REM)PRCB CN31-5 (LOCK) | bizhub 364e 21-Jbizhub 284e 23-Jbizhub 224e 24-J |
5 | PRCB ICP3 conduction check | – | – |
6 | Replace FRB (Part# A61FH00500) | – | – |
7 | Replace PRCB (Part# A61FH00101) | – | – |
- Link to the wiring diagram (N.1. bizhub 364e/284e/224e)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.11.1 (Link to the Field Service Manual)