93-10 (bizhub C364/C284/C224)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
JAM type | Misfeed at duplex transport section | |
JAM code | 93-10 | |
Detection timing | The ADU paper passage sensor/2 (PS41) is not blocked even after the set period of time has elapsed after the ADU paper passage sensor/1 (PS40) is unblocked by the paper. | |
– | In case the ADU paper passage sensor/1 (PS40) is unblocked or the ADU paper passage sensor/2 (PS41) is blocked after main power switch is turned ON, door and cover are opened / closed or jam/trouble reset is done, it is regarded as paper jam at duplex transport section. | |
– | In case the registration sensor (PS1) is unblocked after main power switch is turned ON, door and cover are opened / closed or jam/trouble reset is done, it is regarded as paper jam at duplex transport section. | |
– | In case paper position is detected as locating properly after main power switch is turned ON, door and cover are opened / closed or jam/trouble reset is done, it is regarded as paper jam at duplex transport section. | |
Misfeed processing location | Duplex door | |
Relevant parts | -Transport motor (M1) -ADU transport motor (M5) -ADU transport clutch (CL6) -Registration sensor (PS1) -ADU paper passage sensor/1 (PS40) -ADU paper passage sensor/2 (PS41) -Front side board (FRB) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
2 | PS1 I/O check, sensor check | FRB CN8-3 (ON) | 4 to 5-L |
3 | PS40 I/O check, sensor check | PRCB CN21-10 (ON) | 18-C |
4 | PS41 I/O check, sensor check | PRCB CN21-13 (ON) | 18-C |
5 | CL6 operation check | FRB CN12-11 (ON) | 26-C |
6 | M1 operation check | PRCB CN31-2 (REM)PRCB CN31-5 (LOCK) | bizhub C364 21-Jbizhub C284 22-Jbizhub C224 24-J |
7 | M5 operation check | PRCB CN21-1 to 4 | 17 to 18-C |
8 | PRCB ICP31, IC27 conduction check | – | – |
9 | Replace FRB (Part# A161H00501) | – | – |
10 | Replace PRCB (Part# A161H00108) | – | – |
- Link to the wiring diagram (N.1. bizhub C364/C284/C224)
K1.11.2 (Link to the Field Service Manual)