99-09 (bizhub 364e/284e/224e)
Contents
JAM type | Controller JAM (finisher not completing a job) | |
JAM code | 99-09 | |
Detection timing | • A paper exit or paper finishing process inside the finisher is not completed. • The finisher does not start during a reset procedure from the jam. | |
Misfeed processing location | – | |
Relevant parts | – |
(2)Procedure
Step | Action | Control signal | Location of electrical component |
1 | Initial check items | – | – |
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.1.11.11 (Link to the Field Service Manual)