C0104, C0105 (bizhub 650i/550i/450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0104: Tray 3/4 feeder transportation motor failure to turn (When PC-417 is installed) C0105: Tray 3/4 feeder transportation motor turning at abnormal timing (When PC-417 is installed) |
Rank | B |
Trouble detection condition | C0104: The control circuit detects motor failure to turn while the motor is turning. C0105: The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | Tray 3/4 |
Relevant electrical parts | -Transport motor (M152) -PC control board (PCCB) |
Procedure
- Check the connector between M152-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M152 for proper drive coupling and correct as necessary.
- M152 load check
- Check code: 28
- Multi code:
56, 57, 58, 59 (bizhub 650i)
56, 58, 59 (bizhub 550i)
56, 57, 59 (bizhub 450i) - Control signal: PCCB CN5-1 to 8
- Location of electrical component: 7-K
- Replace M152. (Part# A7PUM11100)
- PCCB F300 conduction check
- Replace PCCB. (Part# AAV5H01401)