C0105 (bizhub C754/C654)
Contents
Trouble type | Tray 3/4 feeder transportation motor turning at abnormal timing |
Trouble code | C0105 |
Rank | B |
Detection timing | The lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -LCC transport motor (M25) -Paper feed/transport drive board (PFTDB) -Printer control board (PRCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M25-PFTDB CN17 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M25 for proper drive coupling and correct as necessary. | – | – |
3 | M25 operation check | PFTDB CN17-1 to 7 | 11-X |
4 | Replace M25 (Part# A161M10200) | – | – |
5 | PFTDB ICP6 conduction check | – | – |
6 | Replace PFTDB (Part# A2X0H00202) | – | – |
7 | Replace PRCB (Part# A2X0H00102) | – | – |
- Link to the wiring diagram (N.1. bizhub C754/C654)
- Link to the layout drawings for related parts by each trouble code (S.2. C0104, C0105)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.5.2 (Link to the Field Service Manual)