C0107: Tray 3/LCT vertical transport motor turning at abnormal timing (When PC-113, PC-213 or PC-413 is installed)
B
-The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
-The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
<When PC-113 or PC-213 is installed>
-Tray 3 vertical transport motor (M112)
-PC control board (PCCB)
<When PC-413 is installed>
-Vertical transport motor (M132)
-PC control board (PCCB)

 Procedure

 When PC-113 or PC-213 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-113/PC-213 3 to 4-C
  4. Replace M112. (Part# A7VAM10000)
  5. Replace PCCB. (PC-113 Part# A7VAH00100 / PC-213 Part# A7VAH00200)

NOTICE

  • Link to the wiring diagram (PC-113)
  • Link to the wiring diagram (PC-213)

 When PC-413 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-413 4 to 5-J
  4. Replace M132. (Part# A7VAM10000)
  5. Replace PCCB. (Part# A7VAH00300)

NOTICE

  • Link to the wiring diagram (PC-413)

K.3.7.3 (Link to the Field Service Manual)