C0107 (bizhub 287/227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
C0107: Tray 3/LCT vertical transport motor turning at abnormal timing (When PC-113, PC-213 or PC-413 is installed) |
B |
-The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. -The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary. |
– |
<When PC-113 or PC-213 is installed> -Tray 3 vertical transport motor (M112) -PC control board (PCCB) |
<When PC-413 is installed> -Vertical transport motor (M132) -PC control board (PCCB) |
Procedure
When PC-113 or PC-213 is installed
- Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M112 for proper drive coupling and correct as necessary.
- M112 operation check
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-113/PC-213 3 to 4-C
- Replace M112. (Part# A7VAM10000)
- Replace PCCB. (PC-113 Part# A7VAH00100 / PC-213 Part# A7VAH00200)
NOTICE
When PC-413 is installed
- Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
- Check the connector of M132 for proper drive coupling and correct as necessary.
- M132 operation check
- Control signal: PCCB CN5-13 (CW/CCW)
- Location of electrical component: PC-413 4 to 5-J
- Replace M132. (Part# A7VAM10000)
- Replace PCCB. (Part# A7VAH00300)
NOTICE
- Link to the wiring diagram (PC-413)
K.3.7.3 (Link to the Field Service Manual)