How Can We Help?

C0107 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeTray 3/LCT vertical transport motor turning at abnormal timing
Trouble codeC0107
RankB
Detection timing• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-110 or PC-210 is installed>
• Tray 3 vertical transport motor (M112)
• PC control board (PCCB)
<When PC-410 is installed>
• Vertical transport motor (M132)
• PC control board (PCCB)

 (2)ProcedureWhen PC-110 or PC-210 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
2Check the connector of M112 for proper drive coupling and correct as necessary.
3M112 operation checkPCCB CN5-13 (CW/CCW)PC-110/PC-210 3 to 4-C
4Replace M112 (Part# A2XMM10000)
5Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)

When PC-410 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
2Check the connector of M132 for proper drive coupling and correct as necessary.
3M132 operation checkPCCB CN5-13 (CW/CCW)PC-410 4-J
4Replace M132 (Part# A2XMM10000)
5Replace PCCB (PC-410 Part# A2XMH00301))
  • Link to the wiring diagram (N.2.5 PC-410)
  • Link to the layout drawings for related parts by each trouble code (S.3.2 PC-410)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.3 (Link to the Field Service Manual)

Table of Contents