C0107 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeTray 3/LCT vertical transport motor turning at abnormal timing
Trouble codeC0107
RankB
Detection timing• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-110 or PC-210 is installed>
• Tray 3 vertical transport motor (M112)
• PC control board (PCCB)
<When PC-410 is installed>
• Vertical transport motor (M132)
• PC control board (PCCB)

 (2)ProcedureWhen PC-110 or PC-210 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
2Check the connector of M112 for proper drive coupling and correct as necessary.
3M112 operation checkPCCB CN5-13 (CW/CCW)PC-110/PC-210 3 to 4-C
4Replace M112 (Part# A2XMM10000)
5Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)

When PC-410 is installed

StepActionControl signalLocation of electrical components
1Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
2Check the connector of M132 for proper drive coupling and correct as necessary.
3M132 operation checkPCCB CN5-13 (CW/CCW)PC-410 4-J
4Replace M132 (Part# A2XMM10000)
5Replace PCCB (PC-410 Part# A2XMH00301))
  • Link to the wiring diagram (N.2.5 PC-410)
  • Link to the layout drawings for related parts by each trouble code (S.3.2 PC-410)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.3 (Link to the Field Service Manual)