How Can We Help?

C0107 (bizhub 558/458)

You are here:

Contents

Trouble typeC0107: Tray 3/transfer LCT vertical transport motor’s turning at abnormal timing (When PC-110, PC-210, or PC-410 is installed)
RankB
Trouble detection condition• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-110 or PC-210 is installed>
• Tray 3 vertical transport motor (M112)
• PC control board (PCCB)
<When PC-410 is installed>
• Vertical transport motor (M132)
• PC control board (PCCB)

 Procedure

 When PC-110 or PC-210 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-110/PC-210 3 to 4-C
  4. Replace M112. (Part# A2XMM10000)
  5. Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)

NOTICE

  • Link to the wiring diagram (PC-110)
  • Link to the wiring diagram (PC-210)

 When PC-410 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-410 4-J
  4. Replace M132. (Part# A2XMM10000)
  5. Replace PCCB. (Part# A2XMH00301)

NOTICE

  • Link to the wiring diagram (PC-410)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.3 (Link to the Field Service Manual)

Table of Contents