How Can We Help?

C0107 (bizhub 650i/550i/450i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

When PC-116 or PC-216 is installed

Contents

Trouble typeC0107: Tray 3 vertical transport motor turning at abnormal timing (When PC-116 or PC-216 is installed)
RankB
Trouble detection condition-The control circuit detects motor failure to turn while the motor is turning.

-The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Tray 3 vertical transport motor (M112)
-PC control board (PCCB)

Procedure

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 load check
    • Check code: 28
    • Multi code:
      6, 7, 8, 9 (bizhub 650i)
      6, 8, 9 (bizhub 550i)
    • 6, 7, 9 (bizhub 450i)
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-116/PC-216 3 to 4-C
  4. Replace M112. (Part# A2XMM11000)
  5. Replace PCCB.
    PC-116 (Part# AAV5H00101)
    PC-216 (Part# AAV5H00201)

 When PC-416 is installed

Contents

Trouble typeC0107: Transfer LCT vertical transport motor turning at abnormal timing (When PC-416 is installed)
RankB
Trouble detection condition-The control circuit detects motor failure to turn while the motor is turning.

-The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Vertical transport motor (M132)
-PC control board (PCCB)

Procedure

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 load check
    • Check code: 28
    • Multi code:
    • 21, 22, 23, 24 (bizhub 650i)
    • 21, 23, 24 (bizhub 550i)
    • 21, 22, 24 (bizhub 450i)
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-416 4-J
  4. Replace M132. (Part# A2XMM11000)
  5. Replace PCCB. (Part# AAV5H00300)

 When PC-417 is install

 When PC-417 is installed

Contents

Trouble typeC0107: Intermediate motor turning at abnormal timing (When PC-417 is installed)
RankB
Trouble detection condition-The control circuit detects motor failure to turn while the motor is turning.

-The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Intermediate motor (M151)
-PC control board (PCCB)

Procedure

  1. Check the connector between M151-relay CN73-PCCB CN20 for proper connection and correct as necessary.
  2. Check the connector of M151 for proper drive coupling and correct as necessary.
  3. M151 load check
    • Check code: 28
    • Multi code:
    • 56, 57, 58, 59 (bizhub 650i)
    • 56, 58, 59 (bizhub 550i)
    • 56, 57, 59 (bizhub 450i)
    • Control signal: PCCB CN20-1 to 3
    • Location of electrical component: PC-417 7-K
  4. Replace M151. (Part# AAV5M11000)
  5. Replace PCCB. (Part# AAV5H01401)

(Link to the Field Service Manual)

Table of Contents