Trouble typeC0107: Tray 3/transfer LCT vertical transport motor turning at abnormal timing (When PC-115, PC-215, or PC-415 is installed)
RankB
Trouble detection condition• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-115 or PC-215 is installed>
• Tray 3 vertical transport motor (M112)
• PC control board (PCCB)
<When PC-415 is installed>
• Vertical transport motor (M132)
• PC control board (PCCB)

 Procedure

 When PC-115 or PC-215 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 load check
    • Check code: 28
    • Multi code: 17, 18, 19, 20
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-115/PC-215 3 to 4-C
  4. Replace M112. (Part# A2XMM11000)
  5. Replace PCCB. (Part# A2XMH00101)

 When PC-415 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 load check
    • Check code: 28
    • Multi code: 5, 6, 7, 8
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-415 4-J
  4. Replace M132. (Part# A2XMM11000)
  5. Replace PCCB. (Part# A2XMH00301)