How Can We Help?

C0107 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC0107: Tray 3/transfer LCT vertical transport motor’s turning at abnormal timing (When PC-115, PC-215, or PC-415 is installed)
RankB
Trouble detection condition•The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
•The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Trouble isolation
Relevant electrical parts<When PC-115 or PC-215 is installed>Tray 3 vertical transport motor (M112)PC control board (PCCB)
<When PC-415 is installed>Vertical transport motor (M132)PC control board (PCCB)

 Procedure

 When PC-115 or PC-215 is installed

  1. Check the connector between M112-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M112 for proper drive coupling and correct as necessary.
  3. M112 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-115/PC-215 3 to 4-C
  4. Replace M112. (Part# A2XMM11000)
  5. Replace PCCB. (PC-115 Part# A2XMH00101/ PC-215 Part# A2XMH00201)

NOTICE

  • Link to the wiring diagram (PC-115)
  • Link to the wiring diagram (PC-215)

 When PC-415 is installed

  1. Check the connector between M132-PCCB CN5 for proper connection and correct as necessary.
  2. Check the connector of M132 for proper drive coupling and correct as necessary.
  3. M132 operation check
    • Control signal: PCCB CN5-13 (CW/CCW)
    • Location of electrical component: PC-415 4-J
  4. Replace M132. (Part# A2XMM11000)
  5. Replace PCCB. (Part# A2XMH00301)

NOTICE

  • Link to the wiring diagram (PC-415)

Please review all part numbers for accuracy and current version.