C0107 (bizhub C750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0107: Intermediate motor turning at abnormal timing |
Rank | B |
Trouble detection condition | -The control circuit detects motor failure to turn while the motor is turning. -The control circuit detects motor turning while the motor remains stationary. |
Trouble isolation | – |
Relevant electrical parts | -Intermediate motor (M151) -PC control board (PCCB) |
Procedure
- Check the connector between M151-relay CN73-PCCB CN20 for proper connection and correct as necessary.
- Check the connector of M151 for proper drive coupling and correct as necessary.
- M151 load check
- Check code: 28
- Multi code: 56, 57, 58, 59, 60
- Control signal: PCCB CN20-1 to 3
- Location of electrical component: Cabinet (Tray 3/4) 7-K
- Replace M151. (Part# AAV5M11000)