Trouble type | C0108: Tray 4 drive motor malfunction (When PF-P27 or PF-P28 is installed) |
Rank | B |
Trouble detection condition | The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning. |
Trouble isolation | Tray 4 |
Relevant electrical parts | <When PF-P27 or PF-P28 is installed> | Tray 4 drive motor (M1/4)Tray 4 PC control board (PCCB/4)CPU board (CPUB)Base board (BASEB) |
Procedure
- Check the connector between M1/4-PCCB/4 CN4 for proper connection and correct as necessary.
- Check the connector between PCCB/4 CN1-relay CN2PC-PCCB/3 CN2 for proper connection and correct as necessary.
- Check the connector between PCCB/3 CN1-relay CN2PC-PCCB/2 CN2 for proper connection and correct as necessary.
- Check the connector between PCCB/2 CN1-relay CN24-BASEB CN21E for proper connection and correct as necessary.
- Check the connector of M1/4 for proper drive coupling and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- M1/4 load check
- Check code: 28
- Multi code: 5, 6
- Control signal: PCCB/4 CN4-1 to 7
- Location of electrical component: 19-P
- Replace M1/4.
- PCCB/4 F1 and F2 conduction check
- Replace PCCB/4.
- Replace CPUB.
- Replace BASEB.