How Can We Help?

C0109 (bizhub 360i/300i)

You are here:

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

Contents

Trouble typeC0109: Tray 4 vertical transport motor turning at abnormal timing (When PC-216 is installed)
RankB
Trouble detection condition-The control circuit detects motor failure to turn while the motor is turning.

-The control circuit detects motor turning while the motor remains stationary.
Trouble isolation
Relevant electrical parts-Tray 4 vertical transport motor (M122)
-PC control board (PCCB)

Procedure

  1. Check the connector between M122-PCCB CN9C for proper connection and correct as necessary.
  2. Check the connector of M122 for proper drive coupling and correct as necessary.
  3. M122 load check
    • Check code: 28
    • Multi code: 26, 29, 30
    • Control signal: PCCB CN9-13 (CW/CCW)
    • Location of electrical component: PC-216 6-K
  4. Replace M122. (Part# A2XMM11000)
  5. Replace PCCB. (Part# AAV5H00201)

(Link to the Field Service Manual)

Table of Contents