How Can We Help?

C0202 (bizhub 554e/454e)

You are here:

Contents

Trouble type Tray 1 feeder up/down abnormality
Trouble code C0202
Rank B
Detection timing The tray 1 upper limit sensor (PS25) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolation Tray 1
Relevant electrical parts • Tray 1 lift-up motor (M12)
• Tray 1 upper limit sensor (PS25)
• Printer control board (PRCB)

  (2)Procedure

Step Action Control signal Location of electrical components
1 Check the connector between M12-PRCB CN25 for proper connection and correct as necessary.
2 Check the connector of M12 for proper drive coupling and correct as necessary.
3 Check the connector between PS25-relay CN30-PRCB CN26 for proper connection and correct as necessary.
4 PS25 I/O check, sensor check PRCB CN26-3 (ON) 7-C
5 M12 operation check PRCB CN25-5 (REM) 1-C
6 Replace M12M12 (Part# 9J06M10300)
7 PRCB ICP5 conduction check
8 Replace PRCBPRCB (Part# 554e A61DH00101 454e A61EH00101)

Document Information ID D0001134237 Revise ID R000003

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.6 (Link to the Field Service Manual)

Table of Contents