How Can We Help?

C0202 (bizhub 558/458)

You are here:

Contents

Trouble typeC0202: Tray 1 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 1
Relevant electrical parts• Tray 1 lift-up motor (M12)
• Tray 1 upper limit sensor (PS25)
• MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M12-MFPB CN27E for proper connection and correct as necessary.
  3. Check the connector of M12 for proper drive coupling and correct as necessary.
  4. Check the connector between PS25-relay CN30-MFPB CN34E for proper connection and correct as necessary.
  5. PS25 I/O check, sensor check
    • Control signal: MFPB CN34E<B>-3 (ON)
    • Location of electrical component: 27-J
  6. M12 operation check
    • Control signal: MFPB CN27E-5 (M12_24V)
    • Location of electrical component: 19-J
  7. Replace M12. (Part# 9J06M10300)
  8. MFPB F1E conduction check
  9. Replace MFPB. (558 Part# A9HGH02102 / 458 Part# A9HHH02102)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.8.6 (Link to the Field Service Manual)

Table of Contents