How Can We Help?

C0202 (bizhub C554e/C454e)

You are here:

(1)Contents

Trouble typeTray 1 feeder up/down abnormality
Trouble codeC0202
RankB
Detection timingThe tray 1 upper limit sensor (PS25) is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Trouble isolationTray 1
Relevant electrical parts• Tray 1 lift-up motor (M12)
• Tray 1 upper limit sensor (PS25)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M12-PRCB CN25 for proper connection and correct as necessary.
2Check the connector of M12 for proper drive coupling and correct as necessary.
3Check the connector between PS25-relay CN30-PRCB CN26 for proper connection and correct as necessary.
4PS25 I/O check, sensor checkPRCB CN26-3 (ON)7-C
5M12 operation checkPRCB CN25-5 (REM)1-C
6Replace M12 (Part # ( 9J06M10300)
7PRCB ICP5 conduction check
8Replace PRCB (C554e Part# A5AYH00101 / C454e Part# A5C0H00101)