C0202 (bizhub C650i/C550i/C450i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0202: Tray 1 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 1 |
Relevant electrical parts | -Tray 1 lift-up motor (M12) -Tray 1 upper limit sensor (PS25) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M12-relay CN180-BASEB CN25E for proper connection and correct as necessary.
- Check the connector of M12 for proper drive coupling and correct as necessary.
- Check the connector between PS25-relay CN30-BASEB CN26E for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS25 I/O check, sensor check
- Control signal: BASEB CN26EA-15 (ON)
- Location of electrical component: 11-K
- M12 load check
- Check code: 23
- Multi code: 4
- Control signal: BASEB CN25E-1 (REM)
- Location of electrical component: 17-K
- Replace M12. (Part# 9J06M10300)
- Replace CPUB. (C450i Part# AA7RH02P02 / C550i Part# AA7PH02P01 / C650i Part# AA7NH02P03)
- Replace BASEB. (Part# AA7NH02102)
L.3.7.7 (Link to the Field Service Manual)