How Can We Help?

C0202 (bizhub C658/C558/C458)

You are here:

Contents

Trouble typeC0202: Tray 1 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 1 upper limit sensor (PS25) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 1
Relevant electrical parts•Tray 1 lift-up motor (M12)
•Tray 1 upper limit sensor (PS25)
•MFP board (MFPB)

 Procedure

  1. Remove thetray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M12-MFPB CN27E for proper connection and correct as necessary.
  3. Check the connector of M12 for proper drive coupling and correct as necessary.
  4. Check the connector between PS25-relay CN30-MFPB CN34E for proper connection and correct as necessary.
  5. PS25 I/O check, sensor check
    • Control signal: MFPB CN34E<B>-3 (ON)
    • Location of electrical component: 27-J
  6. M12 operation check
    • Control signal: MFPB CN27E-5 (M12_24V)
    • Location of electrical component: 19-J
  7. Replace M12. (Part# 9J06M10300)
  8. MFPB F1E conduction check
  9. Replace MFPB. (C458 Item# 9 Part# A79MH02102 / C558 or C658 Item # 9 Part # A79JH02102)

NOTICE

Please verify all parts for accuracy and current version.

K.3.8.6 (Link to the Field Service Manual)

Table of Contents