C0204 (bizhub 658e/558e/458e)

You are here:

Contents

Trouble typeC0204: Tray 2 feeder up/down abnormality
RankB
Trouble detection conditionThe tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 2
Relevant electrical partsTray 2 lift-up motor (M13)Tray 2 upper limit sensor (PS22)MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M13-MFPB CN32E for proper connection and correct as necessary.
  3. Check the connector of M13 for proper drive coupling and correct as necessary.
  4. Check the connector between PS22-relay CN40-MFPB CN34E for proper connection and correct as necessary.
  5. PS22 I/O check, sensor check
    • Control signal: MFPB CN34E<A>-9 (ON)
    • Location of electrical component: 26-I
  6. M13 load check
    • Check code: 23
    • Multi code: 5
    • Control signal: MFPB CN32E-5 (M13_REM)
    • Location of electrical component: 20-I
  7. Replace M13. (Part# 9J06M10300)
  8. MFPB F1E conduction check
  9. Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

L.3.7.9 (Link to the Field Service Manual)