C0204 (bizhub 658e/558e/458e)
Contents
Trouble type | C0204: Tray 2 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 2 upper limit sensor (PS22) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 2 |
Relevant electrical parts | Tray 2 lift-up motor (M13)Tray 2 upper limit sensor (PS22)MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M13-MFPB CN32E for proper connection and correct as necessary.
- Check the connector of M13 for proper drive coupling and correct as necessary.
- Check the connector between PS22-relay CN40-MFPB CN34E for proper connection and correct as necessary.
- PS22 I/O check, sensor check
- Control signal: MFPB CN34E<A>-9 (ON)
- Location of electrical component: 26-I
- M13 load check
- Check code: 23
- Multi code: 5
- Control signal: MFPB CN32E-5 (M13_REM)
- Location of electrical component: 20-I
- Replace M13. (Part# 9J06M10300)
- MFPB F1E conduction check
- Replace MFPB. (658e/558e Part# AA6RH02103 / 458e Part# AA6UH02101)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
L.3.7.9 (Link to the Field Service Manual)