How Can We Help?
C0206 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS156) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Tray 3 lift-up motor (M143) -Tray 3 upper limit sensor (PS156) -PC control board (PCCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M143-PCCB CN6 for proper connection and correct as necessary.
- Check the connector of M143 for proper drive coupling and correct as necessary.
- Check the connector between PS156-relay CN25-PCCB CN7 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS156 I/O check, sensor check
- Control signal: PCCB CN7-9 (ON)
- Location of electrical component: PC-417 4-C
- M143 load check
- Check code: 23
- Multi code: 6
- Control signal: PCCB CN6-4 to 5
- Location of electrical component: PC-417 5-K
- Replace M143. (Part# A2X0M12101)
- PCCB PS300 conduction check
- Replace PCCB. (Part# AAV5H01401)
- Replace CPUB. (Part# ACV7H02P02)
- Replace BASEB. (Part# ACV7H02101)