C0206 (bizhub 750i)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0206: Tray 3 feeder up/down abnormality |
Rank | B |
Trouble detection condition | The tray 3 upper limit sensor (PS156) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Tray 3 lift-up motor (M143) -Tray 3 upper limit sensor (PS156) -PC control board (PCCB) -CPU board (CPUB) -Base board (BASEB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M143-PCCB CN6 for proper connection and correct as necessary.
- Check the connector of M143 for proper drive coupling and correct as necessary.
- Check the connector between PS156-relay CN25-PCCB CN7 for proper connection and correct as necessary.
- Check CPUB for proper installation and correct as necessary.
- PS156 I/O check, sensor check
- Control signal: PCCB CN7-9 (ON)
- Location of electrical component: PC-417 4-C
- M143 load check
- Check code: 23
- Multi code: 6
- Control signal: PCCB CN6-4 to 5
- Location of electrical component: PC-417 5-K
- Replace M143. (Part# A2X0M12101)
- PCCB PS300 conduction check
- Replace PCCB. (Part# AAV5H01401)
- Replace CPUB. (Part# ACV7H02P02)
- Replace BASEB. (Part# ACV7H02101)