How Can We Help?

C0206 (bizhub C368/C308/C258)

You are here:

Contents

Trouble typeC0206: Tray 3 feeder up/down abnormality (When PC-110 or PC-210 is installed)
RankB
Trouble detection conditionThe tray 3 upper limit sensor (PS116) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
Trouble isolationTray 3
Relevant electrical parts•Tray 3 lift-up motor (M113)
•Tray 3 upper limit sensor (PS116)
•PC control board (PCCB)
•MFP board (MFPB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M113-PCCB CN6 for proper connection and correct as necessary.
  3. Check the connector of M113 for proper drive coupling and correct as necessary.
  4. Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary.
  5. PS116 I/O check, sensor check
    • Control signal: PCCB CN4-3 (ON)
    • Location of electrical component: PC-110/PC-210 7-C
  6. M113 operation check
    • Control signal: PCCB CN6-8 to 9
    • Location of electrical component: PC-110/PC-210 2-C
  7. Replace M113. (Part# 9J06M10300)
  8. Replace PCCB. (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201)
  9. Replace MFPB. (Part# A7PUH02123)

NOTICE

  • Link to the wiring diagram (PC-110)
  • Link to the wiring diagram (PC-210)

Please review all part numbers for accuracy and current version.

K.3.7.8 (Link to the Field Service Manual)

Table of Contents