C0206 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | Tray 3 lift-up failure |
Trouble code | C0206 |
Rank | B |
Detection timing | The tray 3 upper limit sensor (PS116) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Tray 3 lift-up motor (M113) -Tray 3 upper limit sensor (PS116) -PC control board (PCCB) -MFP board (MFPB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M113-PCCB CN6 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M113 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS116-relay CN24-PCCB CN4 for proper connection and correct as necessary. | – | – |
4 | PS116 I/O check, sensor check | PCCB CN4-3 (ON) | PC-110/PC-210 7-C |
5 | M113 operation check | PCCB CN6-8 to 9 | PC-110/PC-210 2-C |
6 | Replace M113 (Part# 9J06M10300) | – | – |
7 | Replace PCCB (PC-110 Part# A2XMH00101 / PC-210 Part# A2XMH00201) | – | – |
8 | Replace MFPB (Part# A2XKH02004) | – | – |
- Link to the wiring diagram (N.3.1 PC-110)
- Link to the wiring diagram (N.3.2 PC-210)
- Link to the layout drawings for related parts by each trouble code (S.8. C0206)
K3.5.8 (Link to the Field Service Manual)