C0208 (bizhub 368/308)
Contents
Trouble type | C0208: Tray 4 feeder up/down abnormality (When PC-210 is installed) |
Rank | B |
Trouble detection condition | The tray 4 upper limit sensor (PS126) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. |
Trouble isolation | Tray 4 |
Relevant electrical parts | • Tray 4 lift-up motor (M123) • Tray 4 upper limit sensor (PS126) • PC control board (PCCB) • MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M123-PCCB CN8 for proper connection and correct as necessary.
- Check the connector of M123 for proper drive coupling and correct as necessary.
- Check the connector between PS126-relay CN47-PCCB CN7 for proper connection and correct as necessary.
- PS126 I/O check, sensor check
- Control signal: PCCB CN7-3 (ON)
- Location of electrical component: PC-210 8-K
- M123 operation check
- Control signal: PCCB CN8-8 to 9
- Location of electrical component: PC-210 5-K
- Replace M123. (Part# 9J06M10300)
- Replace PCCB. (PC-110/PC-210) (Part# A2XMH00101/Part# A2XMH00201)
- Replace MFPB. (Part# A9HJH02102)
NOTICE
- Link to the wiring diagram (PC-210)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
K.3.7.9 (Link to the Field Service Manual)