C0210 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0210: LCT lift failure (When PC-414 is installed) |
Rank | B |
Trouble detection condition | -The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. -The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-up operation for the drawer began. -The main tray upper limit sensor (PS136) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-up operating. -The main tray upper limit sensor (PS136) is not turned OFF (unblocked) even after the set period of time has elapsed after the paper lift-down operation began. -The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the paper lift-down operation began. |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Main tray upper limit sensor (PS136) -Shifter stop / lower limit position sensor (PS138) -Elevator motor (M134) -PC control board (PCCB) -MFP board (MFPB) |
Procedure
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M134-PCCB CN10L for proper connection and correct as necessary.
- Check the connector of M134 for proper drive coupling and correct as necessary.
- Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary.
- Check the connector between PS138-relay CN16-PCCB CN14L for proper connection and correct as necessary.
- PS136 I/O check, sensor check
- Control signal: PCCB CN4-3 (ON)
- Location of electrical component: PC-414 8-J
- PS138 I/O check, sensor check
- Control signal: PCCB CN14L-6 (ON)
- Location of electrical component: PC-414 4-J
- M134 operation check
- Control signal: PCCB CN10L-1 to 2
- Location of electrical component: PC-414 6-J
- Replace M134. (Part# A2XMM10100)
- Replace PCCB. (Part# A7VAH00300)
- MFPB F11E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
- Link to the wiring diagram (PC-414)
K.3.7.10 (Link to the Field Service Manual)