How Can We Help?

C0210 (bizhub C554/C454)

You are here:

Contents

Trouble typeLCT lift failure
Trouble codeC0210
RankB
Detection timing-The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
-The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the paper lift-up operation for the drawer began.
-The main tray upper limit sensor (PS136) is not blocked even after the set period of time has elapsed after the paper lift-up operating.
-The main tray upper limit sensor (PS136) is not unblocked even after the set period of time has elapsed after the paper lift-down operation began.
-The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the paper lift-down operation began.
Trouble isolationLCT
Relevant electrical parts-Main tray upper limit sensor (PS136)
-Shifter stop / lower limit position sensor (PS138)
-Elevator motor (M134)
-PC control board (PCCB)

(2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M134-PCCB CN10 for proper connection and correct as necessary.
2Check the connector of M134 for proper drive coupling and correct as necessary.
3Check the connector between PS136-relay CN1-PCCB CN4 for proper connection and correct as necessary.
4Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary.
5PS136 I/O check, sensor checkPCCB CN4-3 (ON)PC-410 8-J
6PS138 I/O check, sensor checkPCCB CN14-6 (ON)PC-410 4-J
7M134 operation checkPCCB CN10-1 to 2PC-410 6-J
8Replace M134 (Part# A2XMM10100)
9PCCB IC2 conduction check
10Replace PCCB (Part# A2XMH00301)
  • Link to the wiring diagram (N.3.3 PC-410)
  • Link to the layout drawings for related parts by each trouble code (S.10. C0210)

K3.5.10 (Link to the Field Service Manual)

Table of Contents