C0211 (bizhub 364e/284e/224e)

You are here:

Contents

Trouble typeManual feed up/down abnormality
Trouble codeC0211
RankB
Detection timing• Paper does not unblock the bypass lift-up position sensor (PS26) even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
• The bypass lift-up position sensor (PS26) is not blocked even after the transport motor (M1) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Trouble isolationManual
Relevant electrical parts• Transport motor (M1)
• Bypass pick-up solenoid (SD1)
• Bypass lift-up position sensor (PS26)
• Printer control board (PRCB)

 (2)Procedure

StepActionControl signalLocation of electrical components
1Check the connector between M1-PRCB CN31 for proper connection and correct as necessary.
2Check the connector of M1 for proper drive coupling and correct as necessary.
3Check the connector between PS26-relay CN19-PRCB CN27 for proper connection and correct as necessary.
4Check the connector between SD1-relay CN21-relay CN19-PRCB CN27 for proper connection and correct as necessary.
5PS26 I/O check, sensor checkPRCB CN27-13 (ON)4-C
6SD1 operation checkPRCB CN27-10 (ON)4-C
7M1 operation checkPRCB CN31-2 (REM)PRCB CN31-5 (LOCK)bizhub 364e 21-I to Jbizhub 284e 23-I to Jbizhub 224e 24-I to J
8Replace M1 (Part# A161M10001)
9PRCB ICP5 conduction check
10Replace PRCB (Part# A61FH00101)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.5.11 (Link to the Field Service Manual)