C0211 (bizhub 958/808)

You are here:

Contents

Trouble typeC0211: Manual feed up/down abnormality
RankB
Trouble detection condition• The bypass upper limit sensor (PS35) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
• The bypass lower limit sensor (PS36) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Trouble isolationManual
Relevant electrical parts• Bypass lift-up motor (M26)
• Bypass upper limit sensor (PS35)
• Bypass lower limit sensor (PS36)
• Paper feed/transport drive board (PFTDB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M26-relay CN195B-PFTDB CN9 for proper connection and correct as necessary.
  2. Check the connector of M26 for proper drive coupling and correct as necessary.
  3. Check the connector between PS35-relay CN195B-PFTDB CN9 for proper connection and correct as necessary.
  4. Check the connector between PS36-relay CN180-relay CN195A-PFTDB CN3 for proper connection and correct as necessary.
  5. PS35 I/O check, sensor check
    • Control signal: PFTDB CN9-12 (ON)
    • Location of electrical component: 12-P
  6. PS36 operation check
    • Control signal: PFTDB CN3-13 (ON)
    • Location of electrical component: 11-P
  7. M26 operation check
    • Control signal: PFTDB CN9-1 to 2
    • Location of electrical component: 11 to 12-P
  8. Replace M26. (Part# A0P0R75200)
  9. PFTDB F17 conduction check
  10. Replace PFTDB. (Part# A796H00200)
  11. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.7 (Link to the Field Service Manual)