How Can We Help?

C0211 (bizhub 958/808)

You are here:

Contents

Trouble typeC0211: Manual feed up/down abnormality
RankB
Trouble detection condition• The bypass upper limit sensor (PS35) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
• The bypass lower limit sensor (PS36) is not turned ON (blocked) even after the bypass lift-up motor (M26) rotates for a given period of time after the position is switched from stand by position at lift-up plate to the feed position.
Trouble isolationManual
Relevant electrical parts• Bypass lift-up motor (M26)
• Bypass upper limit sensor (PS35)
• Bypass lower limit sensor (PS36)
• Paper feed/transport drive board (PFTDB)
• MFP board (MFPB)

 Procedure

  1. Check the connector between M26-relay CN195B-PFTDB CN9 for proper connection and correct as necessary.
  2. Check the connector of M26 for proper drive coupling and correct as necessary.
  3. Check the connector between PS35-relay CN195B-PFTDB CN9 for proper connection and correct as necessary.
  4. Check the connector between PS36-relay CN180-relay CN195A-PFTDB CN3 for proper connection and correct as necessary.
  5. PS35 I/O check, sensor check
    • Control signal: PFTDB CN9-12 (ON)
    • Location of electrical component: 12-P
  6. PS36 operation check
    • Control signal: PFTDB CN3-13 (ON)
    • Location of electrical component: 11-P
  7. M26 operation check
    • Control signal: PFTDB CN9-1 to 2
    • Location of electrical component: 11 to 12-P
  8. Replace M26. (Part# A0P0R75200)
  9. PFTDB F17 conduction check
  10. Replace PFTDB. (Part# A796H00200)
  11. Replace MFPB. (Part# A796H02003)

NOTICE

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.6.7 (Link to the Field Service Manual)

Table of Contents