How Can We Help?

C0214 (bizhub 368/308)

You are here:

Contents

Trouble typeC0214: Transfer LCT shift failure (When PC-410 is installed)
RankB
Trouble detection condition• The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the shift operation began (shift to the right).
• The shifter home sensor (PS139) is not turned OFF (unblocked) even after the set period of time has elapsed after the shift operation began (shift to the right).
• The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the return operation began (shift to the left).
• The shifter home sensor (PS139) is not turned ON (blocked) even after the set period of time has elapsed after the return operation began (shift to the left).
Trouble isolationLCT
Relevant electrical parts• Shifter stop / lower limit position sensor (PS138)
• Shifter home sensor (PS139)
• Shifter motor (M133)
• PC control board (PCCB)

 Procedure

  1. Remove the tray and check to see if a piece of paper is not left inside the machine.
  2. Check the connector between M133-PCCB CN10 for proper connection and correct as necessary.
  3. Check the connector of M133 for proper drive coupling and correct as necessary.
  4. Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary.
  5. Check the connector between PS139-relay CN16-PCCB CN14 for proper connection and correct as necessary.
  6. PS138 I/O check, sensor check
    • Control signal: PCCB CN14-6 (ON)
    • Location of electrical component: PC-410 3-J
  7. PS139 I/O check, sensor check
    • Control signal: PCCB CN14-3 (ON)
    • Location of electrical component: PC-410 4-J
  8. M133 operation check
    • Control signal: PCCB CN10-3 to 4
    • Location of electrical component: PC-410 6-J
  9. Replace M133. (Part# A2XMM10100)
  10. Replace PCCB. (Part# A2XMH00301)

NOTICE

  • Link to the wiring diagram (PC-410)

Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.

K.3.7.12 (Link to the Field Service Manual)

Table of Contents