C0214 (bizhub C287/C227)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | C0214: LCT shift failure (When PC-414 is installed) |
Rank | B |
Trouble detection condition | -When the paper removal method and the correct paper setting method are displayed on the operation panel three times. -The shifter stop / lower limit position sensor (PS138) is not turned ON (blocked) even after the set period of time has elapsed after the shift operation began (shift to the right). -The shifter home sensor (PS139) is not turned OFF (unblocked) even after the set period of time has elapsed after the shift operation began (shift to the right). -The shifter stop / lower limit position sensor (PS138) is not turned OFF (unblocked) even after the set period of time has elapsed after the return operation began (shift to the left). -The shifter home sensor (PS139) is not turned ON (blocked) even after the set period of time has elapsed after the return operation began (shift to the left). |
Trouble isolation | Tray 3 |
Relevant electrical parts | -Shifter stop / lower limit position sensor (PS138) -Shifter home sensor (PS139) -Shifter motor (M133) -PC control board (PCCB) -MFP board (MFPB) |
Procedure
- Check the paper for proper set and correct as necessary.
- Remove the tray and check to see if a piece of paper is not left inside the machine.
- Check the connector between M133-PCCB CN10L for proper connection and correct as necessary.
- Check the connector of M133 for proper drive coupling and correct as necessary.
- Check the connector between PS138-relay CN16-PCCB CN14L for proper connection and correct as necessary.
- Check the connector between PS139-relay CN16-PCCB CN14L for proper connection and correct as necessary.
- PS138 I/O check, sensor check
- Control signal: PCCB CN14L-6 (ON)
- Location of electrical component: PC-414 4-J
- PS139 I/O check, sensor check
- Control signal: PCCB CN14L-3 (ON)
- Location of electrical component: PC-414 4-J
- M133 operation check
- Control signal: PCCB CN10L-3 to 4
- Location of electrical component: PC-414 6-J
- Replace M133. (Part# A2XMM10100)
- Replace PCCB. (Part# A7VAH00300)
- MFPB F11E conduction check
- Replace MFPB. (Part# A797H02118)
NOTICE
- Link to the wiring diagram (PC-414)
K.3.7.12 (Link to the Field Service Manual)