C0214 (bizhub C554/C454)
Please search Knowledge Base articles and Bulletins as they may contain relevant information and updated Part information such as Part numbers.
Contents
Trouble type | LCT shift failure |
Trouble code | C0214 |
Rank | B |
Detection timing | -The shifter stop / lower limit position sensor (PS138) is not blocked even after the set period of time has elapsed after the shift operation began (shift to the right). -The shifter home sensor (PS139) is not unblocked even after the set period of time has elapsed after the shift operation began (shift to the right). -The shifter stop / lower limit position sensor (PS138) is not unblocked even after the set period of time has elapsed after the return operation began (shift to the left). -The shifter home sensor (PS139) is not blocked even after the set period of time has elapsed after the return operation began (shift to the left). |
Trouble isolation | LCT |
Relevant electrical parts | -Shifter motor (M133) -Shifter stop / lower limit position sensor (PS138) -Shifter home sensor (PS139) -PC control board (PCCB) |
(2)Procedure
Step | Action | Control signal | Location of electrical components |
1 | Check the connector between M133-PCCB CN10 for proper connection and correct as necessary. | – | – |
2 | Check the connector of M133 for proper drive coupling and correct as necessary. | – | – |
3 | Check the connector between PS138-relay CN16-PCCB CN14 for proper connection and correct as necessary. | – | – |
4 | Check the connector between PS139-relay CN16-PCCB CN14for proper connection and correct as necessary. | – | – |
5 | PS138 I/O check, sensor check | PCCB CN14-6 (ON) | PC-410 4-J |
6 | PS139 I/O check, sensor check | PCCB CN14-3 (ON) | PC-410 4-J |
7 | M133 operation check | PCCB CN10-3 to 4 | PC-410 6-J |
8 | Replace M133 (A2XMM10100) | – | – |
9 | PCCB IC2 conduction check | – | – |
10 | Replace PCCB (Part# A2XMH00301) | – | – |
- Link to the wiring diagram (N.3.3 PC-410)
- Link to the layout drawings for related parts by each trouble code (S.12. C0214)
K3.5.12 (Link to the Field Service Manual)